電站測溫用熱電阻
WZC-130B,WZP-220B,WZP-221B,WZP-230B,WZP-231B,WZP2-220B,WZP2-221B,WZP2-230B,WZP2-231B,WZP-220AB,WZP2-220AB。WZC-220B,WZC-230B,WZC-220AB,WZP-320B,WZP-321B,WZP-330B,WZP-331B,WZP2-320B,WZP2-321B,WZP2-330B,WZP2-330B,WZC-320B,WZC-320B,WZP-420B,WZP-421B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZC-420B,WZC-430B,WZP-420B,WZP-421B,WZP-430B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZP-420B,WZC-430B,WZP-621B,WZP-621AB,WZP-631B,WZP2 -621B,WZP2 -621B,WZP2 -631B,WZP-621B,WZP-631B,WZP-621B,WZP2 -631B,WZP-621AB,WZP2-621AB,WZP-002,WZP-003,WZP-003A,WZCM-201,WZPM-201,WZPM-201,WZP-270S,WZP-26S,WZP-236SB,
量程規格
名稱
|
分度號
|
測(cè)溫範圍℃
|
精度等(děng)級
|
允差Δt
|
鎳鉻-鎳矽熱電偶
|
K
|
0~800
|
2
|
±2.5℃或(huò) ±0.75%t
|
鎳鉻-銅鎳熱電偶
|
E
|
0~600
|
2
|
±2.5℃或 ±0.75%t
|
鉑(bó)熱電阻
|
Pt100
|
-200~500
|
B
|
±(0.3+0.005|t|)
|
注:t為感溫元件實測溫度或實測溫度的(de)絕對值。
□公稱壓力
一般是指在常溫下,保護管(guǎn)所能承受的靜態外壓(yā)而不破(pò)裂,試驗(yàn)壓力(lì)一般采用(yòng)公稱壓力的1.5倍。實際上,允許工作壓(yā)力不僅與保護管材料、直徑、壁厚有關,而且還與其結構形式、安裝方法、置(zhì)入深度以及被測介質的流(liú)速、種類有關。
□熱電偶絕緣電阻
常溫絕(jué)緣電阻的試(shì)驗電壓為(wéi)直流500V。測量常溫絕緣電阻的大氣條件(jiàn)為:溫度15~35℃,相對濕度45%RH,大氣壓力86~106kPa。
對於長度超過1米的熱電偶,它的常溫絕緣電(diàn)阻值(zhí)與其長度的乘(chéng)積應不小於100MΩ•m,
即:Rr•L>100MΩ•mL>1m
式中:Rr-熱電偶的常溫絕緣電阻值,MΩ;
L-熱電偶的長度,m。
對於長度等於或(huò)不足1米的熱電偶,它(tā)的常溫絕緣電阻值應不小於100MΩ。
□熱電阻絕緣電阻
常溫絕(jué)緣電阻的試驗電壓(yā)可取直流10~100V任意值,環境溫度應在15~35℃範圍內,相對濕度應(yīng)不大於80%RH,常溫(wēn)絕緣電阻值應不小(xiǎo)於(yú)100MΩ。
□熱電阻允許通過電流
通過鉑電阻的(de)測量電流最大不超(chāo)過5mA。
|